Assessment and preparation · Lesson 6 of 22
Investigate deck leaks and wet core
Water can travel along a fastener, between layers or behind a liner before appearing below. Mark the suspected entry, the observed exit and every inaccessible section between them. Comparative moisture readings can help a surveyor map an area, but nearby metal and construction changes can affect readings.
Workshop exercise
Draw a plan view of the deck fitting above a cabin stain. Take a second photograph from below and align both using a fixed feature. Separate direct observations from suspected routes. Do not seal the visible exit and assume the source has been found.

Check your understanding
Does one high reading beside a metal backing plate establish rotten core?
Show the reasoning
No. Corroborate the reading against comparable construction and a professional assessment.
Further reading · WEST SYSTEM Fiberglass Boat Repair & Maintenance manual