← Fiberglass course syllabus

Assessment and preparation · Lesson 6 of 22

Investigate deck leaks and wet core

Water can travel along a fastener, between layers or behind a liner before appearing below. Mark the suspected entry, the observed exit and every inaccessible section between them. Comparative moisture readings can help a surveyor map an area, but nearby metal and construction changes can affect readings.

Fastener · Suspected water route (schematic)

Workshop exercise

Draw a plan view of the deck fitting above a cabin stain. Take a second photograph from below and align both using a fixed feature. Separate direct observations from suspected routes. Do not seal the visible exit and assume the source has been found.

Surveying a boat
Surveying a boat · Boatyard context

Check your understanding

Does one high reading beside a metal backing plate establish rotten core?

Show the reasoning

No. Corroborate the reading against comparable construction and a professional assessment.

Further reading · WEST SYSTEM Fiberglass Boat Repair & Maintenance manual