Yamaha F4B water-pump impeller replacement
6EC portable four-stroke
Match the parts to your motor
6EE-W0078-01
Yamaha’s 6EC listing identifies this pump kit. Ask the supplier to cross-reference the full serial to the latest revision. Inventory the insert, impeller, outer plate, gasket and water seal before starting.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
The F4B lower-unit removal page distinguishes two shift positions: neutral during propeller removal, then reverse to expose the joints behind the covers. Follow its lettered drawing to identify both joints before lowering the gearcase.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Check that the insert registers in the housing and that its outlet aligns with the water passage. Retain the dowel locations and inspect the rubber seals shown on the pump-and-shift-rod sheet.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.