← Water-pump workshop

Tohatsu MFS6C water-pump impeller replacement

2014 C-series parts catalog

Match the parts to your motor

369873222M (supersedes 369873221M)

Cross-check the current kit with the C-series assembly-kit sheet. The gearcase drawing lists impeller 369-65021-1 and upper case 369-65016-0 independently. Confirm whether you also need the case before placing the order.

Upper case 369-65016-0Impeller 369-65021-1Guide plate and gasket
Component locator, schematic. Use the model drawing below for actual shapes, fasteners and assembly order.
Open the Tohatsu MFS6C pump reference ↗

Prepare and disconnect the shift linkage

Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.

Locate shift-rod joint 7-26 in the C-series controls drawing and identify its retainer in the assembly. Keep the joint adjustment recorded. Use the service procedure for the fitted shaft length to establish access before lowering the supported gearcase.

Inspect and rebuild the pump

Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.

Compare gearcase figure 8 with the kit drawing. Set aside each dowel and drive component by location. A replacement impeller cannot correct a damaged upper case or a water tube missing its seal.

Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.

Verify shifting and cooling

With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.

No cooling after the repair?

With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.

Additional model or parts reference ↗