← Water-pump workshop

Tohatsu M50D2 water-pump impeller replacement

D2 two-stroke, 2017 parts drawing

Match the parts to your motor

3C8-87322-3

The M40D2 and M50D2 share the repair kit. Select the M50D2 column for parts outside the kit, and compare the upper pump case and water-tube seal with the installed leg before reusing them.

Housing and outletDriven impellerGasket 3T5-65018-2
Component locator, schematic. Use the model drawing below for actual shapes, fasteners and assembly order.
Open the Tohatsu M50D2 pump reference ↗

Prepare and disconnect the shift linkage

Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.

Check shaft length and locate the cam rod and linkage joint in the D2 drawings. Support the gearcase while releasing the service connection using the model procedure. Document the linkage position before moving any adjustment.

Inspect and rebuild the pump

Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.

Check the gasket number against figure 14, then match the ports to the guide plate before closing the pump. If cooling disappeared immediately after prior lower-unit work, inspect tube alignment and hub engagement before ordering another rotor.

Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.

Verify shifting and cooling

With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.

No cooling after the repair?

With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.

Additional model or parts reference ↗