Tohatsu M40D2 water-pump impeller replacement
D2 two-stroke; gearcase figure 14
Match the parts to your motor
3C8-87322-3
Match the D2 designation before ordering. The two-stroke M40C appears under a different repair kit in Tohatsu’s application table. Record the installed gearcase identification if the leg has been replaced.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
The gearcase drawing distinguishes cam rods by transom length. Match your shaft length and identify the accessible linkage connector in the shop instructions. Do not loosen an internal cam retainer simply because the leg is still held up.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Locate guide plate 14-26 and case gasket 14-28 on the drawing. Keep the old gasket as a port-pattern reference. Confirm gear selection after reconnecting the linkage and water flow only with an approved cooling supply.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.