Tohatsu M18E2 water-pump impeller replacement
Two-stroke; 2017 parts catalog
Match the parts to your motor
362-87322-1
Use the two-stroke M18E2 column in the catalog. Inspect whether the installed pump uses standard or chrome-plated wear components. The accessory list and the drawing distinguish the standard repair kit from optional plated components.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
Follow the control rod to the connector identified in the M18E2 gearcase and control drawings. Confirm the model procedure for releasing its retainer and record the selector position before lowering the supported unit.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Keep the plate and gaskets in order while comparing their openings. Confirm the replacement plate suits the installed case and that the drive piece seats fully in the hub before following the factory housing installation sequence.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.