Suzuki DF6A water-pump impeller replacement
A-series, 2017 onward; verify serial
Match the parts to your motor
17400-98661
This pump repair kit is listed within maintenance kit 17400-91891. Compare its contents with the upper panel and sleeve, which are listed separately in the broader service kit. The earlier DF6 uses a different catalog.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
Find the clutch-rod connector on the CLUTCH LEVER sheet and trace it to the SHIFT ROD sheet for the exact serial. Use the matching shop procedure for access and release; the DF2.5 K6 power-unit removal sequence belongs to another design.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Check the sleeve for scoring as well as inspecting the vanes. A new rotor running against a grooved surface can leave the original cooling complaint unresolved. Inspect the tube seal before aligning the gearcase.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.