Suzuki DF5A water-pump impeller replacement
A-series four-stroke, 2017 onward
Match the parts to your motor
17400-98661 catalog pump kit
The Suzuki selector lists this pump kit inside maintenance kit 17400-91891. Recent catalogs may list a superseding pump kit. Verify by serial and compare the sleeve and upper panel against the items actually supplied.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
Find the clutch-rod connection in the A-series shift drawings. Identify the designated release point with the matching service manual before loosening gearcase fasteners. Keep the old DF5 and the DF5A procedures separate when matching the leg.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Inspect the sleeve and upper panel even when the vanes appear to be the only damaged parts. If a polished groove catches a fingernail, compare the part with the manual’s replacement criteria before reusing it.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.