Suzuki DF40A water-pump impeller replacement
standard A-series, 2010–2023 catalog coverage
Match the parts to your motor
17400-88L01
Check the last character on the identification plate. The AV gearcase has a separate pump listing even when its horsepower matches.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
Use the Suzuki DF40A service manual to identify the linkage release and specified shift position. Photograph the joint before separation so you can check its alignment when the gearcase goes back on.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Lay out the Suzuki DF40A pump parts in removal order. Account for the key, compare both wear surfaces with the manual’s inspection limits and check that the gasket openings match the water passages before assembly.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.