Johnson 10R78M water-pump impeller replacement
1978 9.9 HP
Match the parts to your motor
0391698 catalog repair kit
The original gearcase drawing lists kit 0391698 and housing 0388289. Verify the housing actually fitted before ordering, since later service replacements may already be installed. Note the extension-specific callouts if the leg has been changed.
Prepare and disconnect the shift linkage
Secure the motor upright, disable starting as its manual directs and support the gearcase separately. Identify the required shift position, connector and fasteners before loosening the leg.
Locate the connector between the upper and lower shift rods in the gearcase assembly. Support the leg while identifying the coupling and its retaining screw. Follow the 1978 procedure to engage the rod correctly before securing the connector.
Inspect and rebuild the pump
Lift the housing in the service-manual sequence. Count the vanes and investigate any missing pieces in the downstream water passages. Check the plate and cup for scoring, then lay out the replacement parts beside the drawing.
Compare the old housing with the original catalog drawing before laying out the kit. Check the water-tube entry and extension parts for shaft-length applicability. On reassembly verify shifting separately from water delivery.
Seat the drive key or pin in its specified location. Use the approved lubricant, shaft rotation and bolt torque for this gearcase. Align the shaft, shift connection and delivery tube before closing the joint. If the mating faces resist, separate them and inspect alignment before fastening.
Verify shifting and cooling
With starting disabled, verify shift operation using the model procedure. Restore any drained gear oil and check plugs and fasteners. Test outdoors with the propeller area clear. Supply cooling water by the approved method before cranking and monitor the expected discharge and temperature indications. Shut down for absent expected flow, steam or an alarm.
No cooling after the repair?
With the engine stopped, confirm the intake was supplied with water. Then check for a displaced drive key, a blocked gasket opening, a missed delivery tube or fragments from the old impeller. Record the cause and repeat the cooling check after correction.