← Outboard maintenance

Find an intermittent fuel-hose restriction

A tender that runs well empty but loses power with provisions aboard may have a hose that becomes restricted only in its working position.

Tank exit, Locker edge, Motor turn

1. Recreate the layout with the motor off

Trace the line from tank to connector. Look at locker lids, tank straps, seat edges and cargo. Move the tiller through its permitted range and watch the section at the engine for tension or a tight bend.

2. Correct and verify

Reroute using approved hose and the installation guidance. Replace damaged or permanently creased hose. Secure cargo so the restriction cannot recur, then inspect the primed system for leaks before a controlled trial.

Workshop question

The old hose passes fuel when laid straight on a bench. What has that test missed?

Check your answer

The installed bend, steering movement and cargo pressure that were present when the fault occurred.

Example engine reference · Honda BF4A, BF5D and BF6A owner’s manual. Match the published procedure to your own model and serial range.