Check a manual outboard choke
A cold-start control that stays partly applied can cause a rough warm idle. Verify the system is manually choked before applying this inspection.
1. Observe the actual movement
With the engine stopped and starting disabled, compare the control travel with the model drawing. Where the manual permits inspection, watch the linkage move to both stops. Photograph a slipping cable or disconnected clip before moving it.
2. Separate cold and warm observations
Use the maker’s cold-start sequence and release the choke as specified during warm-up. Record when the trouble begins. Repeatedly pulling the choke on a warm engine can introduce another fault symptom.
Workshop question
The knob returns but the linkage stays partway closed. Should you adjust the idle screw?
Check your answer
Correct the control or linkage first. An idle adjustment would obscure the starting-control fault.
Example engine reference · Honda BF4A, BF5D and BF6A owner’s manual. Match the published procedure to your own model and serial range.