Solar controller reports a battery-temperature sensor fault
Separate a missing or failed temperature measurement from a genuine battery-temperature warning before any charging settings are changed.
When to stop and get help
Use approved shutdown controls and seek urgent help for swelling, unusual heat, odor or smoke. Do not bypass the sensor, disable temperature protection or force charging through an unresolved warning.
Check these first
Read the complete warning
Record the exact code and wording rather than treating every temperature message alike. A sensor-connection fault, high battery temperature and controller overheating describe different conditions and need different responses.
Identify the measurement source
Use the installation record and app device list to establish whether temperature comes from an internal sensor, a wired probe or a networked battery monitor. Note which source the controller currently reports.
Review available readings and history
Compare displayed temperature with previous normal readings and record recent battery, sensor or network work. Do not touch the battery to judge temperature or assume an implausible reading makes continued charging safe.
Arrange charging-system assessment
Provide the battery chemistry, controller model and warning record to the installer. Have the measurement path and charging behavior checked together before restoring normal use or accepting a replacement sensor.
Related maintenance guides
Equipment references
These references describe the listed equipment. Follow the manual for the exact model and installation on your boat.
This checklist supports initial observations. It cannot confirm a diagnosis or that equipment is safe to use. Follow your vessel procedures and equipment manuals, and use qualified marine assistance when needed.