GeneratorsFirst-response checklistUse caution

Generator runs but the boat AC panel has no generator power

Use existing indicators to distinguish engine operation, generator output and acceptance by the boat power system.

When to stop and get help

Do not probe live terminals, bypass a transfer interlock or connect generator output to a shore inlet with improvised leads. Stop use for overheating, arcing, damaged wiring or a persistent output fault.

Check these first

  1. Identify what is actually running

    Record the generator run indication and any installed output-voltage or frequency display. A running engine alone does not establish that usable AC power has reached the boat distribution panel.

  2. Read the selected source and protection state

    Observe the normal source-selector indication and any tripped breaker or transfer-system warning. Compare them with the vessel diagram without opening a switchboard, moving unfamiliar controls or repeatedly resetting protection.

  3. Check inverter or transfer status

    If fitted, record whether the inverter/charger reports waiting, rejected input or accepted AC. Note its displayed input values and whether power briefly appeared before being disconnected.

  4. Arrange inspection of the supply path

    Give an electrician the generator rating, panel observations and recent installation changes. They should distinguish a generator-output problem from transfer, protection or input-quality issues before any operating limits are altered.

Related maintenance guides

Equipment references

These references describe the listed equipment. Follow the manual for the exact model and installation on your boat.

This checklist supports initial observations. It cannot confirm a diagnosis or that equipment is safe to use. Follow your vessel procedures and equipment manuals, and use qualified marine assistance when needed.