ElectricalFirst-response checklistUse caution

Equipment stays powered after its intended service isolator is off

Treat the circuit as energized and establish the real supply arrangement before any maintenance begins; a switch label is not proof of isolation.

When to stop and get help

Never disconnect live battery leads or use a tool to prove power is absent. Preserve bilge-pump and alarm protection; do not defeat an essential supply to make a label appear correct.

Check these first

  1. Stop the planned maintenance

    Keep covers closed and leave wires and terminals untouched. Tell anyone preparing to work that the equipment still responds or shows power despite the expected isolator position.

  2. Identify exactly what remains active

    Record the equipment, display or circuit involved and whether the indication persists. Separate genuinely operating equipment from an indicator whose meaning has not yet been established using its manual.

  3. Compare labels with the wiring record

    Look for separately supplied essential services, multiple banks, remote controls or charging sources on the vessel diagram. Some controls stop operation without providing complete electrical isolation; do not experiment with switches underway.

  4. Request verified isolation and corrected records

    Have an electrician identify the supply paths and check the switch arrangement before service proceeds. Update the circuit labels and shutdown instructions after the actual installation has been confirmed.

Related maintenance guides

Equipment references

These references describe the listed equipment. Follow the manual for the exact model and installation on your boat.

This checklist supports initial observations. It cannot confirm a diagnosis or that equipment is safe to use. Follow your vessel procedures and equipment manuals, and use qualified marine assistance when needed.